Contact Getein
Products
SAA/CRP Quantitative POC Fast Test Kit
SAA/CRP Quantitative POC Fast Test Kit

SAA/CRP Fast Test Kit (Immunofluorescence Assay)

Getein SAA/CRP Fast Test Kit is used as a sensitive index in the diagnosis of infection and inflammation.

  • Test Item:

    SAA/CRP
  • Sample Type:

    Plasma/Serum/Whole Blood/Peripheral blood
  • Test Time:

    5 min
  • Methodology:

    Immunofluorescence Assay

SAA/CRP Fast Test Kit 

(Immunofluorescence Assay)

 


 

Intended Use

SAA/CRP Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of serum amyloid A(SAA)and C-reactive protein (CRP) in serum, plasma, whole blood and fingertip blood. This test can be used as a sensitive index in the diagnosis of infection and inflammation.

 

About SAA/CRP

At present, elevated serum SAA has been detected in various diseases such as bacteria, virus infection, atherosclerosis, coronary heart disease, and acute transplant rejection. SAA provides a clinical auxiliary diagnosis for certain diseases, such as viral infection, transplant rejection, coronary heart disease, etc. The combined detection of SAA and CRP is helpful for the early diagnosis of neonatal sepsis and the identification of bacterial infections from viral infections. The sensitivity of SAA during viral infection is significantly higher than that of CRP, while SAA and CRP are both elevated in patients with a bacterial infection.

 

Specifications

 

Test Item

Sample

Detection Range

Storage Condition

SAA/CRP

P/S/WB/peripheral blood

SAA: 5.0~200.0 mg/L

CRP: 0.5~200.0 mg/L

4-30℃

Method

Test Time

Cut-off Value

Shelf Life

Immunofluorescence

Assay

5 min

SAA: 10.0 mg/L

CRP: 10.0 mg/L

24 months

 

Applicable Device

Getein 1100 Immunofluorescence Quantitative Analyzer

Getein 1600 Immunofluorescence Quantitative Analyzer

 

Clinical Application

1. As a sensitive index in the diagnosis of infection and inflammation.

2. As an aid in the guidance for the use of antibiotic.

3. As an aid in the monitoring and prognostic of trauma and surgery.

4. As an aid in the prognosis of cardiovascular diseases.

 

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.
  • SAA/CRP Quantitative POC Fast Test Kit
Submit
Related Products
CRP Quantitative POC Fast Test Kit CRP Quantitative POC Fast Test Kit
hs-CRP+CRP Fast Test Kit (Immunofluorescence Assay)
>Getein hs-CRP+CRP Fast Test Kit is useful for the detection and evaluation of infection, tissue injury and inflammatory disorders.
PCT/CRP Quantitative POC Fast Test Kit PCT/CRP Quantitative POC Fast Test Kit
PCT/CRP Fast Test Kit (Immunofluorescence Assay)
>Getein PCT/CRP Fast Test Kit is used to identify systemic or local infection, bacterial infection or virus infection, determine the severity of infection and instruct clinical use of antibiotics.
IL-6 Quantitative POC Fast Test Kit IL-6 Quantitative POC Fast Test Kit
IL-6 Fast Test Kit (Immunofluorescence Assay)
>Getein IL-6 Fast Test Kit is used as an aid in the inflammatory diseases.
PCT Quantitative POC Fast Test Kit PCT Quantitative POC Fast Test Kit
PCT Fast Test Kit (Immunofluorescence Assay)
>Getein PCT Fast Test Kit is used as an aid in the assessment and evaluation of patients suspected of bacterial infection, trauma or shock.  
Automatic Clinical Chemistry Analyzer Automatic Clinical Chemistry Analyzer
BBA-300 Automatic Clinical Chemistry Analyzer
>BBA-300 Automatic Clinical Chemistry Analyzer     “No-Wait” Emergency Test Mode  No need of pausing the testing procedure, emergency samples are given test priority and can be tested at any time during analysis. Stable & reliable clinical chemistry test   Highly-Efficient and Convenient Test  Constant test speed of 300 T/h Emergency samples in test priority at any time LIS bi-directional connectivity Automatic test report printing    Multifunctional and Precise Sample Probe  Highly-polished probe Automatic inside and outside probe washing, reducing cross contamination Highly sensitive liquid level detection sensor Actively monitoring reagent volume Protection of probe collision Auto adjustment of sampling depth of sample probe    Sample and Reagent Unit  45 sample positions 90 reagent positions Built-in refrigeration system, continual 24-hour on-board cooling Built-in barcode reader for reagents and samples (optional item)    Reaction Unit  120 cuvettes, can be replaced separately The cuvettes are made of new-type non-crystalline optical plastic with better light transmittance Minimum reaction volume: 150 μL Stable and precise temperature control (37.0 ± 0.2°C) 5-step cuvette Wash Station, thorough cleaning    Stirring Unit  Independent stirring paddle lmported Teflon coating technology Effectively preventing cross contamination    Advanced Operation System  lntuitive user-friendly interface, easy to learn and use Auto sample dilution Auto stopping and warning when reagents or samples run out Calibration with linear or non-linear curves. Multi-point calibration Automatically detecting cuvettes status and screening flawed cuvettes   Technical Parameters   Test Principles Turbidimetry, colorimetry Test Methods End-point method, Rate method, two-point method Test Speed Constant speed of 300 T/h Sample Types Blood, urine, hydrothorax, cerebrospinal fluid Reaction Temperature 37.0 ± 0.2°C (constant temperature) Dimensions Floor-standing: 1060 mm × 660 mm × 1230 mm Benchtop: 1060 mm × 660 mm × 540 mm Weight Floor-standing: 140 kg Benchtop: 85 kg     Floor-standing Benchtop   Test Item     Liver Function TBA, AFU, ALT, AST, ALP, AMM, GGT, TP, GPDA, GLDH, ALB, TB, DB, PA, CHE, ADA, 5’-NT, LAP, MAO, CG, GR Renal Function CRE-E, Urea, UA, β2-MG, CYS-C, MALB, NAG, RBP, CSF Specific Protein and Rheumatism ASO, RF, CRP,  Fer, CCP, Hs-CRP, TRF, RBP, C3, C4, IgA, IgM, IgG Glycometabolism GLU-HK, GLU-OX, FMN, D3-H, HbA1c, GA, LAC, NEFA Blood Lipids and Cardiovascular TG, TCH, HDL-C, LDL-C, ApoA1, ApoB, ApoE, Lp(a), HCY, NEFA, ACE, Myo, Lp-PLA2 Pancreatitis LPS, AMY Venous Thromboembolism and Coagulation D-Dimer Trace Elements and Electrolytes Ca, Mg, P, CO2, Fe, Na, Cl, K, UIBC Myocardial Enzyme CK, CK-MB, CK-MB mass, LDH, HBDH, LDH1 Tumor SA, AFU, Fer, TRF Gastric Function PG Ⅰ, PG Ⅱ      
Leading HCG+β Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading HCG+β Fast Test Kit (Immunofluorescence Assay) Manufacturer
HCG+β Fast Test Kit (Immunofluorescence Assay)
>Getein HCG+β Fast Test Kit is used as an aid in pregnancy test.
Blood Testing Device Blood Testing Device
BHA-5000 Automatic Hematology Analyzer
>BHA-5000 Automatic Hematology Analyzer is employed to count red blood cells, white blood cells, and platelets in blood samples. The results can be used to measure the hemoglobin and calculate relevant parameters of blood cells. It is applicable in hospitals, clinics, and laboratories.
Dengue NS1 Ag Fast Test Kit Dengue NS1 Ag Fast Test Kit
Dengue NS1 Ag Fast Test Kit (lmmunofluorescence Assay)
>Getein Dengue NS1 Ag Fast Test Kit is used as an aid in the early clinical assessment of Dengue virus infection.  
Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service